6-4 General
EXCEEDANCES | WARNINGS RED
The FLTA algorithm has
detected an imminent
ground collision - Initiate an
immediate recovery
maneuver.
The FLTA algorithm has
detected an imminent
obstacle collision - Initiate
an immediate recovery
maneuver.
Unit Overtemp –
Unit Unreliable
Unit Overtemp: <internal
component name> Unit reliability
in question – Get IFD serviced
One or more of the internal
components has exceeded
its maximum design
temperature and reliability
cannot be ensured until the
unit is tested by the Avidyne
Service Center. Contact
the Avidyne Service Center
or a local dealer for service.
This message will be
present on every
subsequent power cycle
until reset by the Avidyne
Service Center.
Low Volts – off in
<countdown from
60> sec
Low Volts – IFD powers down in
<countdown from 60> sec
Main supply voltage has
fallen below 9 VDC.
Contact a local dealer for
service.
Comentários a estes Manuais